Sign In | Join Free | My himfr.com
Home > VLF High Voltage Testing >

High Accuracy VLF High Voltage Testing 60KV High Voltage Vlf Hipot Instruments

    Buy cheap High Accuracy VLF High Voltage Testing 60KV High Voltage Vlf Hipot Instruments from wholesalers
     
    Buy cheap High Accuracy VLF High Voltage Testing 60KV High Voltage Vlf Hipot Instruments from wholesalers
    • Buy cheap High Accuracy VLF High Voltage Testing 60KV High Voltage Vlf Hipot Instruments from wholesalers

    High Accuracy VLF High Voltage Testing 60KV High Voltage Vlf Hipot Instruments

    Ask Lasest Price
    Brand Name : Fanke High-voltage
    Model Number : VLF-60KV/0.1Hz
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 20 sets / month
    Delivery Time : 10-15working days
    • Product Details
    • Company Profile

    High Accuracy VLF High Voltage Testing 60KV High Voltage Vlf Hipot Instruments

    60KV Very Low Frequency Test Set For Cable , VLF Cable Tester , HV Test , Generator Insulation


    I. Application :


    Model VLF-60KV/0.1Hz is designed to perform on-site withstand voltage test with very-low frequency test frequency for power generators or 35KV and below XLPE power cable.Compared with Hipot test set at main power frequency, VLF HV Test Set just needs much small test power capacity(About 1/500 in theory). Its size and weight also is decreased greatly. Specially the appearance of surveillance can discover the generator insulation abnormal phenomena such as surface corona, discharge and so on.


    VLF hipot tester combines modern advanced digital variable frequency technology and micro computer control together, therefore, it can realize the full automatic voltage boost, stepdown, measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display, and can display the output wave form. The printer outputs test reports


    The test set consists of a control box, one HV boosters, a compensation capacitor and a discharge rod.Based on electronic frequency conversion and microprocessor controlled technology, it has excellent performance on cable or generator testing.


    II. Supply list of this Model:


    Sn

    Description

    Qty.

    1

    Control unit

    1

    unit

    2

    60KV HV Booster

    1

    unit

    3

    Discharging rod

    1

    unit

    4

    Load Capacitor, 0.04µF

    1

    unit

    5

    HV Test/Connection Cables

    1

    set

    6

    Earth cable

    1

    unit

    7

    20A Fuse

    5

    unit

    8

    Print paper

    2

    unit

    9

    Manual

    1

    unit

    10

    Factory test report

    1

    unit

    III. Technical Feature
    • The data is accurate because that current, voltage, waveform data are sampled directly from the high voltage side;
    • It has overvoltage protection function. If the output voltage exceeds the set limit value, the instrument will shutdown with an action time less than 20 ms;
    • It has over current protection function. It will shutdown if current exceeds the set value in high voltage side with action time less than 20 ms. And it will shutdown if current exceeds rated current in low voltage side with action time less than 20 ms;
    • A built-in protection resistor and so no need other outside resistor;
    • It adopts high and low voltage closed-loop negative feedback control circuit, and so voltage will not go up due to an inherent capacitance.

    IV. Universal technical data

    1. Output frequency: 0.1Hz, 0.05Hz, 0.02Hz
    2. Measurement accuracy: 3%
    3. Positive and negative voltage peak errors: ≤ 3%
    4. Voltage wave form distortion: ≤ 5%
    5. Use condition: indoor and outdoor; temperature: -10℃+40℃
    6. Humidity: ≤ 85%RH
    7. Power: AC50Hz, 220V ±5%
    V. Optioonal Model and Test Range:
    ModelRated voltageLoading abilityWeightApplication
    VLF-30

    30kV

    (Peak value)

    0.1Hz,≤1.1µF

    Controller:4㎏

    Step-up equipment:25㎏

    Dimension:323*174*323

    10 kV Cable, generator, etc.
    0.05Hz,≤2.2µF
    0.02Hz,≤5.5µF
    VLF-40

    40kV

    (Peak value)

    0.1Hz,≤1.1µF

    Controller:5㎏

    Step-up equipment:30㎏

    Dimension:357*208*343

    13.8 kV Cable, generator, etc.
    0.05Hz,≤2.2µF
    0.02Hz,≤5.5µF
    VLF-50

    50kV

    (Peak value)

    0.1Hz,≤1.1µF

    Controller:6㎏

    Step-up equipment:45㎏

    Dimension:357*210*365

    15.75 kV Cable, generator, etc.
    0.05Hz,≤2.2µF
    0.02Hz,≤5.5µF
    VLF-60

    60kV

    (Peak value)

    0.1Hz,≤1.1µF

    Controller:6㎏

    Step-up equipment:50㎏

    Dimension:357*220*370

    18 kV Cable, generator, etc.
    0.05Hz,≤2.2µF
    0.02Hz,≤5.5µF
    VLF- 80

    80kV

    (Peak value)

    0.1Hz,≤1.1µF

    Controller:8㎏

    Step-up equipment:90㎏

    Dimension:357*240*390

    35 kV Cable, generator, etc.
    0.05Hz,≤2.2µF
    0.02Hz,≤5.5µF



    NOTE : Test Voltage Standard

    1.For cable test

    Test peak voltage formula: Umax=3U0,

    0Single-phase rated voltage of cable

    Test time :60mints


    2. For generator stator

    test=1.414*βKU0,

    Utest---- 0.1Hz peak test voltage (kV);

    β-------0.1Hz and 50Hz voltage equivalent factor, usually taking 1.2;

    K------ Usually take 1.3 to 1.5, generally take 1.5;

    Uo----- Generator stator windings rated voltage (kV);:


    Quality High Accuracy VLF High Voltage Testing 60KV High Voltage Vlf Hipot Instruments for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)