Sign In | Join Free | My himfr.com
Home > AC Resonant Test System >

Overvoltage Protection 270KVA AC Resonant Test System

    Buy cheap Overvoltage Protection 270KVA AC Resonant Test System from wholesalers
     
    Buy cheap Overvoltage Protection 270KVA AC Resonant Test System from wholesalers
    • Buy cheap Overvoltage Protection 270KVA AC Resonant Test System from wholesalers

    Overvoltage Protection 270KVA AC Resonant Test System

    Ask Lasest Price
    Brand Name : Fanke High-voltage
    Model Number : CHX-270KVA/45KV,270KV
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10units/2months
    Delivery Time : 25~45 Work Days
    • Product Details
    • Company Profile

    Overvoltage Protection 270KVA AC Resonant Test System

    AC Resonant Test System for 35KV Cable and 110KV Power Substation Test



    Features:

    • Small size, portable for operating.
    • Screen to show the test data, status and display operation step by real-time.
    • Small temperature rising at rated load. Dry-type epoxy cast, high mechanical strength and good insulation ability.
    • 220V or 380V single phase power source is suitable for on-site sourcing.
    • Different type reactors for optional realize the multipurpose.
    • With over current, over voltage, IPM and discharge protection function.
    • Test result can be printed.


    I. Product Usage :

    This test set model CHX-270KVA/45KV, 270KV is designed for 10KV / 35KV class short XLPE cable ,power transformer, CB,CT/PT, busbar in 110KV power substation to perform on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 45KV ,90KV,270KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive test or hand-over test on AC withstand voltage test


    Test range of the set is as following:transformer

    1. 1000m of 35kV/300mm2 cable, test frequency 30-300Hz, test voltage 52kV, test time 5min.

    2, 3000m of 10kV/300mm2 cable , test frequency 30-300Hz, test voltage 22kV, test time 5min.

    3, 35kV/31500kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 68kV, test time 1min.

    4, 110kV/50000kVA main transformer , capacitance ≤ 0.015uF, test frequency 40-300Hz, test voltage 160kV, test time 1min.

    4, CB,CT/PT, busbar in 110KV power substation , test frequency 40-300Hz, test voltage no more than 265, test time 1min.


    The whole test set consists of variable frequency power source , excitation transformer , 6pieces of reactors, and high voltage measurement devider(capacitive voltage divider). This type of test set is most suitable for 35KV or 110KV power sub-station


    II. General Technical Data


    1. Rated capacity: 270kVA;
    2. Input power: three-phase 380V voltage, frequency is 50Hz;
    3. Rated voltage: 45KV; 270kV;
    4. Rated current: 1A; 6A;
    5. Working frequency: 30-300Hz;
    6. Device output waveform: sine wave
    7. Waveform distortion rate: output voltage waveform distortion rate ≤ 1%;
    8. Working time: continuous 60min allowed under rated load; overpressure 1.1 times 1 minute;
    9. Temperature rise: temperature rise ≤65K after continuous operation for 60 minutes under rated load;
    10. Quality factor: device itself Q≥30 (f=45Hz);
    11. Protection function: Over-current, over-voltage and test product flashover protection for the tested product (see the variable frequency power supply section for details);
    12. Measurement accuracy: system effective value 1.5;


    III. Main Components:


    SNName of ComponentsType and specificationQty.Each weightEach Dimension
    1Variable frequency powerFKVF-20kW/380V1piece35kgs480*480*520mm
    2Excitation transformerCQSB(J)-15kVA/2.5KV,10KV1piece130kgs500*500*580mm
    3HV resonant test reactorCHX(kf)-45kVA/45kV6pieces55kgsD420*H480mm
    4Capacitive dividerTRF-270kV/1000pF1set30kgsD200*H2150mm
    5Special test accessories1set


    VF: Variable Frequency Power Source T : Excitation Transformer
    L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
    C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )


    V. Main Measuring and control software panel:

    Note: This is the software panel before start test for parameter setting



    VI.Accessories

    • Accessory box for storage accessoires
    • Input cables of power source
    • Output cables of power source
    • Output cables of exciting transformer
    • System grounding cables
    • Parallel cables of the reactor
    • HV measuring cables ( the signal output cables of voltage divider )
    • HV output cables(reactor to divide,divider to test object)
    • Insulation supporting base
    • corona ring for 135KV test
    • A final test report, a quality Certificate ,a user manual and a packing list are offered .


    VII. Other Optional Model


    1. For GIS on-site test

    ModelRated voltageRated output currentRated output capacity

    Application

    (From 45Hz starting)

    CHX-135KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-270KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-216KVA/216KV27KV*81A216KVAFor 123KV and below GIS
    CHX-270KVA/270KV27KV*101A270KVAFor 145KV and below GIS
    CHX-275KVA/275KV275KV2A275KVAFor 170KV and below GIS
    Special requirement can be made by order

    2. For 45KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-108/5454KV2A108KVA45kV cable≤1km
    CHX-216/5454KV4A216KVA45kV cable≤2km
    CHX-324/5454KV6A324KVA45kV cable≤3km
    CHX-432/5454KV8A432KVA45kV cable≤4km
    CHX-540/5454KV10A540KVA45kV cable≤5km
    CHX-1080/5454KV20A1080KVA45kV cable≤10km
    Special requirement can be made by order

    3. For 66KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-160/8080KV2A160KVA66kV cable≤0.5km
    CHX-320/8080KV4A320KVA66kV cable≤1km
    CHX-640/8080KV8A640KVA66kV cable≤2km
    CHX-960/8080KV12A960KVA66kV cable≤3km
    CHX-1280/8080KV16A1280KVA66kV cable≤4km
    CHX-1600/8080KV20A1600KVA66kV cable≤5km
    CHX-3200/8080KV40A3200KVA66kV cable≤10km
    CHX-9600/8080KV120A9600KVA66kV cable≤20km
    Special requirement can be made by order

    VIII. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

    Quality Overvoltage Protection 270KVA AC Resonant Test System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)