    Professional Partial Discharge Test Equipment Impulse Current Method PD Tester

    Ask Lasest Price
    Brand Name : Fanke High-Voltage
    Model Number : XD210X series
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10units/month
    Delivery Time : 20~25 work days
    • Product Details
    • Company Profile

    Professional Partial Discharge Test Equipment Impulse Current Method PD Tester

    Digital Partial Discharge Detecting Tester , PD Detecting Instrument , Impulse Current Method PD Tester


    1. Product introduction:


    Due to manufacturing or installation defects, discharge occurs in the insulated portion of the live cable end (joint) until insulation breakdown damage occurs, and even a fire or explosion at uncertain defects may occur. Therefore, how to find the hidden troubles before the accident is the key to solve the problem, which makes the discharge detection necessary for power equipments.


    The model XD2104 is a kind of digital type impulse current method partial discharge inspection instrument It has the feature of small volume, excellent performance and easy operation.


    II. Main Components:


    SNName of equipmentType and specificationUnitQty
    1Host machineXD2104Piece1
    2JZF Series calibratorJZF-10Piece1
    3Amplifierpiece1
    4Input signal unitSN 2, 3,4set1
    5Standard connection wireSet1

    III. Detecting principle figure


    Note : The PD free test transformer set (power frequency voltage withstand test set) rises the target testing voltage to tested object (such as power transformer ,CB, bushing, CT,PT ,discloser and so on )which PD detecting needed , the coupling terminals of voltage divider will has some PD coupling signal to the PD detecting tester JF 2002, then get the PD level from the tested object.


    VI. Technical Parameters of PD tester XD2014


    1. Model: XD2104 Digital detection system of Partial Discharge

    2. Power Supply: 220V AC -5% to +10%

    3. Freq: 50Hz±5%

    4. Environment

    4.1Temperature : -5℃~40℃

    4.2Humidity: < 85%


    5. Security

    • Insulation resistance:> 2MΩ
    • Leakage: < 3.5mA
    • Dielectric strength: the power line right into
    • the chassis can withstand 1500V (50HZ RMS) 1min of the voltage test.

    6.Shape and weight size: 300x350x90(mm) weight:4kg


    7.Host function index

    7.1 CH number: 2,4,6 optional;

    note : XD2102 ---2 channels

    XD2104 ---4 channels

    XD2106 ---6 channels

    7.2 Sensitivity: 0.1pc;

    7.3 Measurement band: 3dB bandwidth of 10kHz-1000kHz

    7.4 Multi-file any combination;

    Lp:10K,20K,40K,80K;Hp:100K,200K,300K,1000K;

    7.5 Gain Range: -20 dB ∽ +40 dB fourth gear can be coarse to fine-tune;

    7.6 Sampling accuracy: 12Bit;

    7.7 Sample Rate:10M /sec.;

    7.8 External Voltage Monitoring: RMS voltage, 14-bit A / D accuracy;

    7.9 Synchronization: internal and external optional,

    external synchronization: 30HZ-600HZ

    automatic synchronization;

    7.10 Sync Input Range: 10V -220V;

    7.11 Linearity error of the range stalls <5% ± 1PC;


    8. External Calibrator(CE)

    • Output standard pulse rising edge <60nS
    • Standard pulse output falling edge> 100uS
    • Standard pulse voltage: 0.5V,1.0V,2.0V,5.0V
    • Calibration capacitors:10pF,100pF
    • Output resistance<100Ω
    • has 12 independent detectionimpedances, each of which provides the tuning capacitor (Ct ')scope on the panel. As long as the detection circuit tuning capacitor resonant capacitor Ct falls within Ct' scope, it is sufficient to meet the requirements of Test Selection Impedance Technical Data Sheet
    NO.Tuning capacitance (Ct´)Maximum Current RMS
    MinimumMedianMaximum

    Unbalanced

    circuit

    Balance

    Circuit

    16pF25pF100pF30mA0.25A
    225pF100pF400pF60mA0.5A
    3100pF400pF1500pF120mA1A
    4400pF1500pF6000pF250mA2A
    51500pF6000pF25nF500mA4A
    725nF100nF400nF2A15A
    8100nF400nF1.5uF4A30A
    9400nF1.5uF6.0uF8A60A
    101.5uF6.0uF25uF15A120A
    116uF25uF60uF25A200A
    1215uF60uF250uF50A300A

    VII. Optional matched other test set

    • PD detecting AC high voltage generating systems : CQSB series PD free power frequency test transformer systems
    • PD signal coupling unit : Coupling voltage divider or standard coupling capacitor , no corona type

    Quality Professional Partial Discharge Test Equipment Impulse Current Method PD Tester for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)