Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle

    Buy cheap Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle from wholesalers
     
    Buy cheap Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle from wholesalers
    • Buy cheap Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle from wholesalers
    • Buy cheap Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle from wholesalers
    • Buy cheap Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle from wholesalers
    • Buy cheap Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle from wholesalers

    Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle

    Ask Lasest Price
    Brand Name : Fanke High-voltage
    Model Number : CHX-275KVA/275KV
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10units/2months
    Delivery Time : 25~45 work days
    • Product Details
    • Company Profile

    Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle

    Portable Variable Frequency Resonant Withstand Voltage Test Set , For 132KV GIS Test


    I. Application :


    This test set model CHX-275KVA/275KV is designed for 132KV and below class GIS on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 275KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints.


    Through modular test reactor is used in parallel , the test set model CHX-275KVA/275KV also can be performed the following AC hipot test:

    • No more than 55KV and 5A for medium voltage XLPE cable , scuh as 45KV and below class.
    • No more than 110KV and 2A for medium voltage XLPE cable , scuh as 66KV and below class.
    • No more than 275KV and 1A for medium voltage GIS , scuh as 132KV~170KV and below class.
    • No more than 55KV and 5A for power motor or generator within 45~55Hz
    • Medium voltage switchgear and power transformer ,scuh as 132KV and below class.

    Until now , these portable designed test set can form many different serialized model according to different medium votage withstand test applications through test reactors in series or in parallel connection and number of configurations in each set, The alike model can see other typical model at the following clause.


    2. Main Components:


    SNName of ComponentsType and specificationQty.Each weightEach Dimension
    1Variable frequency powerFKVF-20kW/380V1piece20kgs440*360*360mm
    2Excitation transformerCQSB(J)-15kVA/15KV,3KV1piece50kgs520*350*550mm
    3HV resonant test reactorCHX(kf)-55kVA/55kV5pieces60kgsD480*H520mm
    4Capacitive dividerTRF-300kV/1000pF1set35kgsD170*H1850mm
    5Special test accessories1set

    Note:1.Load capacitantor can be optional when testing power motor ,generator and power transformer under 45~65Hz.

    2.Test reactor can be produced to be 18KV,20KV,22KV,40KV,44KV, 50KV, 54KV,55KV for each piece according to different tested object scope or customer requried.

    III. Test priciple :


    VF: Variable Frequency Power Source T : Excitation Transformer
    L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
    C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )


    V.Test Wiring Schematic Diagram(for example) :


    V. General Technical data:

    1. Mode of system test: Series resonant with variable frequency
    2. System model : FKTF-275KVA/275KV
    3. Input power supply : 380±10%(three-phase),50Hz/60Hz
    4. Rated inductance parameter: 55KVA/55KV/1A/200H/each
    5. Number of HV test reactor: 5pieces
    6. Rated output capacity: 275kVA
    7. Rated output Voltage: 275KV
    8. Max Test voltage : no more than 275KV
    9. Rated output current: 1A /single piece or in series;5A in parallal
    10. Reg. Freq range : 30Hz-300Hz
    11. Output Resonance voltage waveform: sine wave
    12. THD of output waveform: ≤1%
    13. Insulation level: Under 1.1 times and keeping 1min, normal
    14. Duty cycle : 60mins on under rated current working condition ;
    15. Quality factor of test set itself: Q≥30(at F=30HZ) ;
    16. Temperature rise: Less than 65K under rated current working 60mints;
    17. Noise level: No more than 70B
    18. Reactor Structure: dry type, epoxy tube cylinder type;


    VI. Main Measuring and control software panel:

    Note: This is the software panel before start test for parameter setting

    VII .Delivery wooden case packing list


    Case No.Packed goods nameModel&spec.Goods qty.in the wooden caseWooden case dimension (cm)Case gross weightCase numberRemark
    6-1VF power sourceFKVF-20kW1piece55*47*6045kgs1
    6-2Excitation transformerCQSB(J)-15kVA1piece67*51*87110kgs1
    6-3HV reactorsCHX(kf)-55kVA/55kV5pieces141*98*82619kgs1One case packing
    Accessories boxIncluding test cables and manual1set
    6-4Voltage dividerTRF-300kV-1000pF1piece178*57*5180kgs1
    6-5Corona ring for divider ,reactor1set90*90*9456kgs1One case packing
    Supporting base for divider1piece
    6-6Insulation supporting bases for reactor28KV,165KV each one2pieces63*63*12352kgs1
    Total962kgs6 wooden case



    VIII.Accessories

    • Accessory box for storage accessoires
    • Input cables of power source
    • Output cables of power source
    • Output cables of exciting transformer
    • System grounding cables
    • Parallel cables of the reactor
    • HV measuring cables ( the signal output cables of voltage divider )
    • HV output cables(reactor to divide,divider to test object)
    • Insulation supporting base
    • corona ring for 275KV test
    • A final test report, a quality Certificate ,a user manual and a packing list are offered .


    IX. Other Optional Model


    1. For GIS on-site test

    ModelRated voltageRated output currentRated output capacity

    Application

    (From 45Hz starting)

    CHX-135KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-270KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-216KVA/216KV27KV*81A216KVAFor 123KV and below GIS
    CHX-270KVA/270KV27KV*101A270KVAFor 145KV and below GIS
    CHX-275KVA/275KV275KV2A275KVAFor 170KV and below GIS
    Special requirement can be made by order

    2. For 45KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-108/5454KV2A108KVA45kV cable≤1km
    CHX-216/5454KV4A216KVA45kV cable≤2km
    CHX-324/5454KV6A324KVA45kV cable≤3km
    CHX-432/5454KV8A432KVA45kV cable≤4km
    CHX-540/5454KV10A540KVA45kV cable≤5km
    CHX-1080/5454KV20A1080KVA45kV cable≤10km
    Special requirement can be made by order

    3. For 66KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-160/8080KV2A160KVA66kV cable≤0.5km
    CHX-320/8080KV4A320KVA66kV cable≤1km
    CHX-640/8080KV8A640KVA66kV cable≤2km
    CHX-960/8080KV12A960KVA66kV cable≤3km
    CHX-1280/8080KV16A1280KVA66kV cable≤4km
    CHX-1600/8080KV20A1600KVA66kV cable≤5km
    CHX-3200/8080KV40A3200KVA66kV cable≤10km
    CHX-9600/8080KV120A9600KVA66kV cable≤20km
    Special requirement can be made by order

    X. On-site insulation test standard table from IEC62271-203:2011 for GIS


    XI. On-site insulation test standard table from IEC 60840:2011 for XLPE cable

    Quality Portable AC Resonant Test System For 132KV GIS Test With 60 Mints Duty Cycle for sale